Had the car to a garage yesterday, where they had equipment to refill A/C.
Unfortunately they where not experts handling A/C, on top of this, their automatic filling unit got broke. Fortunately it happened after emptied the system.
I took this opportunity to inspect the pipelines again. No...
The orifice tube was put in as showed in GNT-type.org, with the O-ring in(as the old one).
Sorry, I forgot to mention the accumulator/dryer was also replaced.
I put 2 oz of ester oil(came with the retrofit set) in the accu/dryer, put 2 oz in the compressor and 4 oz was sucked in the system...
I had my AC converted from R12 to R134a today. But the LP was way too high - 150-200 psi. HP was 130-200 psi and should be OK.
We followed the procedure explained at the GNTtype.org, but the pressure-cycling switch acted a little odd. The procedure says:"You can reduce the cycling pressure by...